Calibration Standards

I-STEM’s Library of Standards

The standards available at present are

Thickness Standards

  • Quartz Step Height (450nm) Standard Click here.
  • 20nm Silicon Nitride Film Thickness Standard
  • 200nm Silicon Dioxide Film Thickness Standard
  • 200nm Silicon Nitride Film Thickness Standard

Resistivity Standards

  • 3” Resistivity Standard RS3-3 (0.3 Ω cm)
  • 3” Resistivity Standard RS3-30 (30 Ω cm)

UV-VISIBLE Spectrometer standards

  • (Hellma®️ calibration standard, glass filter set ) Standards concerning stray light, spectral resolution, photometric accuracy and wavelength accuracy for both the UV and the visible range

TEM Calibration standards

  • Reference Standard for Transmission Electron
  • Microscopes (TEM)
  • TEM magnification test specimens
  • Certified Nanosphere Size Standards – 20 nm, 100 nm, 200nm and 500 nm)

XCS EDS Calibration Standards

  • XCS EDS Calibration Standards

SEM magnification calibration

  • SEM magnification calibration

Calibration standard for high resolution X-ray Diffraction (HRXRD)

  • Calibration standard for high resolution X-ray Diffraction (HRXRD)

Diffraction Standards

  • Diffraction standard Camera Length
  • Evaporated Aluminum
  • 500nm Magnification Calibration Diffraction Grating Replica
  • Image Rotation Molybdenum Trioxide
  • 500nm Diffraction Grating Replica with Latex Spheres
  • 2000 l/mm, on 3mm grid
  • Magnification Calibration Diffraction Grating Replicas
  • Diffraction Grating Replica and Latex Calibration Standard
  • Oriented Gold Crystal on 3mm grid

Electrical Standards

  • Multi-Product Calibrator along with 50 turn current Coil
  • Electrical calibration used for the process of verifying the performance of, or adjusting, any instrument that measures or tests electrical parameters.
  • Parameters include voltage, current, resistance, inductance, capacitance, time and frequency.
  • DC voltage from 0 V to ±1020 V.
  • AC voltage from 1 mV to 1020 V, with output from 10 Hz to 500 kHz.
  • AC current from 29 μA to 20.5 A, with variable frequency limits.
  • DC current from 0 to ±20.5 A.
  • Resistance values from a short circuit to 1100 MΩ.
  • Capacitance values from 220 pF to 110 mF.
  • Simulated output for eight types of Resistance Temperature Detectors (RTDs).
  • By using 50 turn current coil, current of current source calibrator by a factor 50.

Weight Calibration Standards

  • Accuracy Class: OIML E1
  • Range of capacity : 1mg to 200g
  • Shape of weights is given below
    • Wire weights: 1mg to 500mg
    • Triangle weights: 1mg, 10mg, 100mg
    • Square weights: 2mg, 20mg, 200mg
    • Pentagon weights:5mg, 50mg, 500mg
    • Cylindrical knob shape: 1g to 200g
    • Reference weight: Austenitic Stainless Steel Calibrated by NSTAR

Capacitance Standards

  • Decade Capacitance Box
    • Decades of 1nF, 10nF, 100nF, 1μF, 10μF Capacitance range: 1nF to 100 μF)
    • Accuracy: 1%

Inductance Standards

  • Decade Induction Box
    • Decades of 10μH, 100μH, 1mH, 10mH, 100mH, 1H (Inductance range: 10 μH to 10H)
    • Accuracy: 1%

Set of 4 wire Low Resistance standards

  • Fixed resistors: 10μ, 50μΩ ,100μΩ, 1mΩ, 10mΩ, 100mΩ, 1000mΩ
  • Maximum Test currents:
    • For 10μΩ, 50μΩ: 20 A
    • For 100μΩ, 1mΩ: 10 A
    • For 100mΩ,10mΩ: 1A
    • For 1000mΩ: 100 mA
  • Accuracy class:
    • 0.25% for 10μΩ, 50μΩ
    • 0.1% for 100μΩ, 1mΩ, 10mΩ, 100mΩ, 1000mΩ

Decade Resistance Box

  • Fixed resistors: 10μ, 50μΩ ,100μΩ, 1mΩ, 10mΩ, 100mΩ, 1000mΩ
  • Maximum Test currents:
    • For 10μΩ, 50μΩ: 20 A
    • For 100μΩ, 1mΩ: 10 A
    • For 100mΩ,10mΩ: 1A
    • For 1000mΩ: 100 mA
  • Accuracy class:
    • 0.25% for 10μΩ, 50μΩ
    • 0.1% for 100μΩ, 1mΩ, 10mΩ, 100mΩ, 1000mΩ