Equipment Info

Orbitrap High Resolution Liquid Chromatograph Mass Spectrometer (HRLCMS)

Equipment Code : 2736837

Make : Thermo Fisher Scientific Pte. Ltd.

Model : Q-Exactive Plus Biopharma-High Resolution Orbitrap

Institution : Sophisticated Analytical Instrument Facilities (SAIF) IIT Bombay

Department : SAIF

Funding Agency Details : DST, Govt. of India

Pooling of Equipment slot :   No

Last AMC Done :  

1 / 1

Reference Website : www.saif.iitb.ac.in

Description : The Orbitrap is an ion trap mass analyzer that consists of two outer electrodes and a central electrode, which enable it to act as both an analyzer and detector. Ions entering the Orbitrap are captured through "electrodynamic squeezing," after which they oscillate around the central electrode and in between the two outer electrodes. Different ions oscillate at different frequencies, resulting in their separation. By measuring the oscillation frequencies induced by ions on the outer electrodes, the mass spectra of the ions are acquired using image current detection. Liquid chromatography / Mass Spectroscopy (LC / MS) is a technique which combines high performance liquid chromatography HPLC, a powerful analytical separation technique with mass spectroscopy,a powerful analysis & detection technique. There are two common atmospheric pressure ionization (API) LC/MS process: Electrospray Ionization (ESI) & Atmospheric Pressure Chemical Ionization (APCI). Both are soft ionization technique.

Usage Rate: (as indicated by the custodian/host institution)

Samples External Academic User Internal Academic User International User Industry User Start-ups National Research Lab User Self (Project Investigator)
Only HRMS
HRMS + compound formula & library search
LCMS with library (Plant extract or Impurity Profiling or Metabolite Identification or Degradation studies or Environmental samples)
Protein Identification (for 1-hour)
Protein Identification (for 2-hours)
Sample Preparation (In-gel or In-solution Trypsin Digestion with Desalting)
Only desalting of digested protein samples
Lipidomics
Intact Mass of Proteins Peptides and Oligonucleotides

Note:

i) Academic (External) means researchers belongs to the other institution.

ii) Academic (Internal but different department/lab) means researchers belongs to other department/lab or other investigators.

iii) Academic (Internal) means researchers belongs to the same institution.


Accessories / Consumables / Spare parts / Testing modes
Sample Name Sample Type Sample UOM Sample Availability Unit Cost Sample Quantity Sample Description
No Data Available